PCEUs

This comprehensive range of one part photo electronic control units and accessories exceeds all specifications for street lighting applications.

Nightstar Series

The ‘Nightstar’ Part night photocell is the ideal unit for applications where energy saving is vital, but the cost and complexity of a remote monitoring and control system is not justified. It is cost effective to purchase, simple to install and offers cost savings from day one of operation.

Nightstar

Sensor type Photo IC
Sensor drift Zero over 10 years
Standard switching level 70 Lux ‘On’, 35 Lux ‘Off’
Switching differential 1:0.5
Operating voltage 90-265 Vac, 50/60 Hz
Maximum lamp load (HID) 2 x 400W inductive (60BF)
Switching cycles 40,000 minimum
Power consumption < 0.25W.
Operating temperature range -20 / +80°C
Warranty 10 years
Ingress protection IP67
Standard Programme Dusk ‘On’ / 2400Hrs ‘Off’ 0530 Hrs ‘On’ / Dawn ‘Off’
Custom Programme Switching points factory programmed to meet Customers requirements.
Optical Performance ##% of stated switching levels

Q Series | V16 Series | V4A Series

The Q18 utilises the highly accurate Microstar 2000 Ultra photocell mounted in a cast Iron housing with a toughened glass window to offer EEx d IIC T6 performance. Ideal for applications where photocell control of lamination is required in any hazardous area.

Q18

Sensor type Filtered Silicon Photodiode
Sensor drift Zero over 10 years
Operating voltage 220 / 270Vac, 50/60 Hz
Maximum lamp load (HID) 3 x 400 W (96>F). 10A (res)
Switching Differential 1:0.5 positive
Standard switching level 70Lux ‘On’, 35 Lux ‘Off’
Power consumption <0.25W
Operating temperature range -20 / +60°C
Weight 5.1 Kg
Earthing Internal and external EEx brass clamps on base and cover
Ingress protection IP66
Warranty 6 years

Q Series | V16 Series | V4A Series

The V16 is compact , attractive and easy to install, ideal for the control of residential lighting installations where switching level adjustment is required.

V16 Adjustable Photocell

Sensor type Cadmium Sulphide
Operating voltage 230 Vac +/- 10%, 50/60 Hz
Maximum lamp load 2200VA, (10A resistive)
Switching Differential 1:1.5 positive
Switching Levels 5—1000 Lux
Switching Delay 10 secs ‘ON’, 40 secs ‘OFF’
Operating temperature range -20 / +80°C
Warranty 2 years
Weight 5.1 Kg
Ingress protection IP54

Q Series | V16 Series | V4A Series

These adjustable photocells with integral ‘press to test’ capability are ideal for control of lighting circuits where lux level adjustment is required along with remote detection. A special ‘reverse acting’ variant is available to meet the special requirements of tunnel and underpass lighting.

V4A and V4071

Sensor type Cadmium Sulphide
Operating voltage 230 Vac +/- 10%, 50/60 Hz
Maximum lamp load (HID) 3 x 400W 960F. 8A (res)
Switching Differential 1:1.5 positive
Switching range 25—50,000 Lux
Power consumption 0.6W
Operating temperature range -20 / +80°C
Warranty 2 years
Ingress protection IP65 (detector),
IP54 (housing)
Options V4071T, Reverse Acting (-ve. switching differential)