Find the specific products you require from the list below
Photo Electric Units
NEMA Base cells
Miniature Cells
2 Part Cells
Special Photocells
Or browse our product lines opposite »

A range of 2 part photocells with the same accuracy, reliability and power consumption as their single part equivalents.
| Sensor type | Unfiltered Silicon photodiode |
| Sensor drift | Zero over 10 years |
| Standard switching level | 70 Lux ‘On’, 35 Lux ‘Off’ |
| Switching differential | 1:0.5 |
| Operating voltage | 220/270 Vac, 50/60 Hz |
| Maximum lamp load (HID) | 3 X 400W inductive (965F),10A |
| Switching cycles | 20,000 minimum |
| Power consumption | 0.25W |
| Operating temp. range | -20 / +80°C |
| Warranty | 6 years |
| Ingress protection | IP65. (detector only) |
| Options | +ve switching differential, switching levels to suit customer requirements. |
| UMSUG Code | 9500000 |
| Sensor type | Filtered Silicon photodiode |
| Sensor drift | Zero over 10 years |
| Standard switching level | 70 Lux ‘On’, 35 Lux ‘Off’ |
| Switching differential | 1:0.5 |
| Operating voltage | 220/270 Vac, 50/60 Hz |
| Maximum lamp load (HID) | 3 X 400W inductive (965F),10A |
| Switching cycles | 20,000 minimum |
| Power consumption | 0.25W |
| Operating temp. range | -20 / +80°C |
| Warranty | 6 years |
| Ingress protection | IP54. (detector only) |
| Options | +ve switching differential, switching levels to suit customer requirements. |
| UMSUG Code | 9500000 |
With its integral 'press to test' facility, the P42 is ideal for applications where remote testing of luminaires is required.
| Sensor Type | Cadmium Sulphide |
| Operating voltage | 220/270 Vac.50/60 Hz |
| Maximum lamp load (HID) | 2 x 250W 60<F. 2000W (res) |
| Switching Differential | 1:1.5 positive |
| Switching Level | 70 Lux |
| Power Consumption | 0.6W |
| Operating temperature range | -15° / +65°C |
| Warranty | 2 years |
| Ingress protection | IP65 (Detector), IP54 (housing) |
| Sensor type | Cadmium Sulphide |
| Standard switching level | 70 Lux |
| Switching differential | 1:1.5 |
| Operating voltage | 220/270 Vac, 50/60 Hz |
| Maximum lamp load (HID) | 2 X 250W inductive (60/F) |
| Maximum Resistive Load | 2000W |
| Power consumption | 0.6W |
| Operating temp. range | -15 / +65°C |
| Warranty | 2 years |
| Ingress protection | IP65. (detector only) |
| Options | Switching levels and wire length to suit customer requirements. |
| Dimensions (mm) | W 31, L 57, D 25, Detector Thread diameter 20. |